Material Database

PtRh10 / Pt-10%Rh

  • General Designation: PtRh10
  • Applications: glass manufacturing, drain bushings, semi-finished products, glass fibre bushings
  • Product Forms: sheet, wire, tube
  • Density (g/cm³): 20

Density - HT

Details

Age Hardenable
No
Material Behaviour
ductile
Forming Process
can be roll clad, formable, machinable

IACS Min. (%) [100% IACS ≙ 58 S*m/mm²]
8.35
IACS Max. (%) [100% IACS ≙ 58 S*m/mm²]
8.6
Electric Resistivity - HT¹
Thermo-emf. vs. copper Hard (mV)
-0.11
Temperature coefficient of electric resistivity
From Temperature (°C)
To Temperature (°C)
Hard (x10-4/K)
Annealed (x10-4/K)
0 100 15.5 16.3
Sources Electrical
¹measured and interpolated

Young's Modulus (GPa)
208
Young's Modulus - HT¹
Modulus of Rigidity (GPa)
72
Yield Strength RP0,2 - HT²
Ult. Tensile Strength Rm - HT³
Tensile Fracture Elongation A - HT⁴
Norton⁵
Creep Rupture⁶
Annealed
Hardness (HV)
Tensile strength (MPa)
Yield strength (MPa)
Elongation (%)
102 300 180 32
Work hardened
Hardness (HV)
Tensile Strength (MPa)
Yield Strength (MPa)
Elongation (%)
204 680 670 1.5
Property Range
Hardness (HV)
Tensile Strength (MPa)
Yield Strength (MPa)
Elongation (%)
102 - 204 300 - 680 180 - 670 1.5 - 32
Sources Mechanical
¹measured | ²measured | ³measured | ⁴measured | ⁵measured and extrapolated | ⁶measured and extrapolated

Melting Range
From Temperature (°C)
To Temperature (°C)
1840 1870
Thermal conductivity (W /(m*K)) [RT]
30
Thermal conductivity - HT¹
Specific Heat - HT²
Linear Coefficient of Expansion³
From Temperature (°C)
To Temperature (°C)
Coefficient (x10-6/K)
20 100 9.07
20 200 8.96
20 300 8.85
20 400 8.93
20 500 9.19
20 600 9.28
20 700 9.56
20 800 9.68
20 900 9.88
Linear Thermal Expansion - HT⁴
From Temperature (°C)
To Temperature (°C)
expansion αL (µm(m*°C))
20 100 8.86
20 200 9.30
20 300 9.74
20 400 9.82
20 500 9.87
20 600 9.94
20 700 10.12
20 800 10.28
20 900 10.41
20 1000 10.50
20 1100 10.60
20 1146 10.74
20 1300 10.88
20 1400 11.01
20 1500 11.23
Sources Thermal
¹measured and interpolated | ²measured and extrapolated | ⁴measured

Disclaimer

The information in this data sheet contains only general information on the use of our products or examples for their application. They do not release the customer from a careful inspection of the delivered product for its fitness for the customer's particular purpose of use. Any customer's special requests regarding the particular use of a product will only be authoritative if Heraeus has confirmed to the customer in writing at the time of conclusion of a corresponding contract that the product delivered is fit for the customer's intended use. Heraeus, therefore, does not guarantee the correctness and completeness of the information regarding the customer's intended use. The customer's purchase will be governed exclusively by the written order confirmation of Heraeus and the Heraeus General Terms of Sale and Delivery, which are available at www.heraeus.com/gtc. This data sheet may be subject to changes at any time.

www.heraeus-precious-metals.com

Discuss your solution

Get in contact with experts to discuss further steps to find the optimal solution for your process.