32209116 - Housed Pt Temperature Sensor

The Pt 1000 PRTD in a standard SOT223 housing is characterized by its standardized signal according to DIN EN 60751 (according to IEC 751), interchangeability, high long time stability and accuracy. It is designed for automatic mounting in electronic applications and serves e.g. for temperature compensation on PCBs. It is equipped with a cooling fin improving thermal contact to the PCB.

32209116

Technical Data

  • Type: SOT223
  • Nominal Resistance R₀ [Ω]: Pt1000
  • Temperature Coefficient (TCR): 3850
  • Tolerance Class: F 0.6 (2B)
  • Min. Temp. °C: -50
  • Max. Temp. °C: 150
  • Min. Tolerance Temp. °C: -50
  • Max. Tolerance Temp. °C: 150
  • Size [mm] (LxW₁xW₂xH): 6.5 / 7 / 3.5 / 1.7
  • Length₂ (mm): 3
  • Connection Technology: Soft Soldering
  • Specific Volume Resistance: 100 °C = 14 X 1014 Ωcm
    150 °C = 0.3 X 1012 Ωcm
  • Physical Data For Housing: Material: duroplastic
    Coefficient of thermal expansion: 12 x 10-6 1 /K (below Tg)
    Thermal Conductivity: 1.04 W/mK
    Moisture absorption: Boiling water (48 hours) < 1.0 %
  • Soldering Connection: Cu alloy with Sn coating
  • Self-Heating: 0.049 K/mW at 0 °C mounted on PCB
    0.2 K/mW at 0 °C package only
  • Packaging: Blister reel
  • Storage Life: 9 months (in original packaging).
    Nitrogen atmosphere recommended

Request a Quote

Do you need more information? Do you want to request a quote? Or haven't you found the perfect sensor? Please contact us and get in touch with our sensor experts worldwide.

©oatawa - stock.adobe.com

The information provided in this data sheet describes certain technical characteristics of the product, but shall not be qualified or construed as quality guarantee (Beschaffenheitsgarantie) in the meaning of sections 443 and 444 German Civil Code. The information provided in this data sheet regarding measurement values (including, but not limited to, response time, long-term stability, vibration and shock resistance, insulation resistance and self-heating) are average values that have been obtained under laboratory conditions in tests of large numbers of the product. Product results or measurements achieved by customer or any other person in any production, test, or other environment may vary depending on the specific conditions of use. The customer is solely responsible to determine whether the product is suited for the customer's intended use; in this respect YAGEO Nexensos cannot assume any liability. The sale of any products by YAGEO Nexensos is exclusively subject to the General Terms of Sale and Delivery of YAGEO Nexensos in their current version at the time of purchase, which is available under www.yageo-nexensos.com/tc or may be furnished upon request. This data sheet is subject to changes without prior notice.